Avena Webapp API - v0.0.1
    Preparing search index...

    Function getTriggerWindows

    • Converts trigger settings into pre and post window lengths.

      The post window is at least 0.01 s. The pre-trigger percent is clamped to 0 to 95 and taken as a share of the whole window, so pre = post * p / (1 - p).

      Parameters

      • settings: TriggerSettings | undefined

        Trigger settings, or undefined for the minimums.

      Returns { postWindowSec: number; preWindowSec: number }

      preWindowSec and postWindowSec, seconds.